HomeTestsSearchRankProfile
100% Free

GATE EE 2017 Question Paper (11-Feb-2017) (Shift 1)

Medium 65 Questions 180 min 100 marks

⚡ Live Test Mode Available

Take this as a timed mock test

180 min · 100 marks · Full test mode with leaderboard

Start Live Test
Advertisement

Previous Year Questions

65medium

5

Questions

0

Attempted

0

Correct

0

Wrong

0/5 attempted

Question No: 56Difficulty: mediumMarks: 2nat
Two parallel connected, three phase, 50 Hz, 11 kV, star-connected synchronous machines A and B, are operating as synchronous condensers. They together supply 50 MVAR to a 11 kV grid. Current supplied by both the machines are equal. Synchronous reactances of machine A and machine B are 1Ω and 3Ω, respectively. Assuming the magnetic circuit to be linear, the ratio of excitation current of machine A to that of machine B is _________. (Give the answer up to two decimal places.)
Question No: 57Difficulty: mediumMarks: 2nat
A 220 V DC series motor runs drawing a current of 30 A from the supply. Armature and field circuit resistances are 0.4 Ω and 0.1 Ω respectively. The load torque varies as the square of the speed. The flux in the motor may be taken as being proportional to the armature current. To reduce the speed of the motor by 50%, the resistance in ohms that should be added in series with the armature is ________. (Give the answer up to two decimal places.)
Question No: 58Difficulty: mediumMarks: 2nat
A three-phase, three winding Δ/Δ/Y (1.1 kV/6.6 kV/400 V) transformer is energized from AC mains at the 1.1 kV side. It supplies 900 kVA load at 0.8 power factor lag from the 6.6 kV winding and 300 kVA load at 0.6 power factor lag from the 400 V winding. The RMS line current in ampere drawn by the 1.1 kV winding from the mains is ___________. (Give the answer up to one decimal place.)
Question No: 59Difficulty: mediumMarks: 2nat
A separately excited DC generator supplies 150 A to a 145 V DC grid. The generator is running at 800 RPM. The armature resistance of the generator is 0.1 Ω. If the speed of the generator is increased to 1000 RPM, the current in amperes supplied by the generator to the DC grid is __________. (Give the answer up to one decimal place.)
Question No: 60Difficulty: mediumMarks: 2nat
For a system having transfer function , a unit step input is applied at time t = 0. The value of the response of the system at t = 1.5 sec (rounded off to three decimal places) is __________.

✓ Showing questions 5660 of 65 — use the page buttons below to practice the rest

You May Also Like

mediumLive Test

PYQs Based test 20: Digital Electronics

20 Qs180m1 attempts
mediumLive Test

PYQs Based test 1: Electric Circuits

20 Qs180m1 attempts
mediumLive Test

GATE EE 2024 Question Paper (11-Feb-2024) (Shift-2)

65 Qs180m
mediumLive Test

GATE EE 2023 Question Paper (05-Feb-2023) (Shift 1)

65 Qs180m
mediumLive Test

GATE EE 2026 Question Paper (14-Feb-2026) (Shift 1)

65 Qs180m
mediumLive Test

GATE EE 2021 Question Paper (07-Feb-2021) (Shift 1)

65 Qs180m

📊 Track Your Progress

Know exactly where you stand

Save scores, track weak topics, compare with toppers — all free.

Advertisement