PYQs Based test 13: Power Systems

Medium 20 Questions 180 min 32 marks

⚡ Live Test Mode Available

Take this as a timed mock test

180 min · 32 marks · Full test mode with leaderboard

Start Live Test
Advertisement

Previous Year Questions

20medium

5

Questions

0

Attempted

0

Correct

0

Wrong

0/5 attempted

Question No: 11Difficulty: mediumMarks: 2mcq
A load is supplied by a 230 V, 50 Hz source. The active power P and the reactive power Q consumed by the load are such that 1 kW ≤ P ≤ 2 kW and 1 kVAR ≤ Q ≤ 2 kVAR. A capacitor connected across the load for power factor correction generates 1 kVAR reactive power. The worst case power factor after power factor connection is
Question No: 12Difficulty: mediumMarks: 2nat
A composite conductor consists of three conductors of radius R each. The conductors are arranged as shown below. The geometric mean radius (GMR) (in cm) of the composite conductor is kR. The value of k is_______.

image
Question No: 13Difficulty: mediumMarks: 1mcq
A 3 – bus power system network consists of 3 transmission lines. The bus admittance matrix of the uncompensated system is

≤ft[ {*20c - j6&j3&j4\\ j3& - j7&j5\\ j4&j5& - j8 } ]Pu

If the shunt capacitance of all transmission lines is 50% compensated, the imaginary part of the 3 row 3 column element (in pu) of the bus admittance matrix after compensation is
Question No: 14Difficulty: mediumMarks: 2nat
The figure shows the single line diagram of a single machine infinite bus system.

image

The inertia constant of the synchronous generator H = 5 MW –s / MVA. Frequency is 50 Hz. Mechanical power is 1 pu. The system is operating at the stable equilibrium point with rotor angle δ equal to 30°. A three phase short circuit fault occurs at a certain location on one of the circuits of the double circuit transmission line. During fault, electrical power in pu is P

sin δ. If the values of δ and dδ / dt at the instant of fault clearing are 45° and 3.762 radian/s respectively, then P (in pu) is___________.
Question No: 15Difficulty: mediumMarks: 2nat
A three phase, 100 MVA, 25kV generator has solidly grounded neutral. The positive, negative, and the zero sequence reactances of the generator are 0.2 pu, 0.2 pu, and 0.05 pu, respectively, at the machine base quantities. If a bolted single phase to ground fault occurs at the terminal of the unloaded generator, the fault current in amperes immediately after the fault is________.

✓ Showing questions 1115 of 20 — use the page buttons below to practice the rest

You May Also Like

mediumLive Test

PYQs Based test 20: Digital Electronics

20 Qs180m1 attempts
mediumLive Test

PYQs Based test 1: Electric Circuits

20 Qs180m1 attempts
mediumLive Test

GATE EE 2024 Question Paper (11-Feb-2024) (Shift-2)

65 Qs180m
mediumLive Test

GATE EE 2023 Question Paper (05-Feb-2023) (Shift 1)

65 Qs180m
mediumLive Test

GATE EE 2026 Question Paper (14-Feb-2026) (Shift 1)

65 Qs180m
mediumLive Test

GATE EE 2021 Question Paper (07-Feb-2021) (Shift 1)

65 Qs180m

📊 Track Your Progress

Know exactly where you stand

Save scores, track weak topics, compare with toppers — all free.

Advertisement